Neurotechnology
Neural lace
A mesh grown painlessly through the whole brain in childhood that gives its owner networked thought, glandular control of mood, memory recording and a backup of the self.
In shortNeural lace, from The Culture series (Iain M. Banks, 1987), is at technology readiness level 2 of 9 (technology concept formulated) at its weakest link. Held back by In-vivo recording of a whole brain at single-neuron resolution. Science status: consistent with known physics; key effects unproven at scale. Estimated new funding to unlock: $114B–564B.
Culture citizens' laces thread through the brain, link them to Minds and the datasphere, and store a mind-state so they can be revived after death.
Closest todaySyringe-injectable mesh electronics and intravenously delivered cell-electronics hybrids in mice; ~1,000-channel human implants.
Dependency stack
Research TRL 1–3Development TRL 4–6Deployment TRL 7–9
Sort by
- Mind-state storage and thought-speed interaction need whole-brain readout
- Optical methods cannot penetrate a human skull or image below ~1 mm of tissue
- Channel count, heat dissipation and uplink bandwidth for ~86 billion neurons
- Displaced tissue volume and vascular damage scale with the number of inserted probes
plausibleTRL 2- Whole-brain coverage needs sensors orders of magnitude smaller than current shanks
✕3 blockers›
- No scheme to individually power and address millions of untethered sub-cellular devices
- Egress bandwidth; nanoparticles can stimulate but cannot yet report spikes off-board
- Clearance, aggregation and long-term toxicity of persistent intraparenchymal devices
plausibleTRL 3- Non-surgical delivery requires crossing from blood into brain parenchyma
✕3 blockers›
- Receptor targeting is species-specific; capsids binding human TfR1 often fail in macaque
- Pre-existing anti-AAV immunity excludes a large fraction of patients and blocks redosing
- Dose needed for brain-wide coverage drives liver toxicity and manufacturing cost
TRL 4- Designed capsid and shuttle proteins are the main route to receptor-specific transcytosis
✕1 blocker›
- Designing catalysis and conformational dynamics
TRL 6
- Devices resident in tissue for decades must not provoke encapsulation
✕3 blockers›
- Micromotion between rigid device and pulsating tissue drives chronic inflammation
- Thin-film encapsulation (polyimide, parylene, SiC) eventually admits water and fails
- Electrode charge-injection limits and corrosion under years of continuous stimulation
TRL 4
- Recording must remain stable for the duration of a life, not monthsTRL 4
- Electrode arrays are today's only route to single-neuron recording in humans
✕2 blockers›
- Tissue response degrades signal over years
- Channel count and wireless bandwidth
TRL 6- Channel count is limited by wireless data and power budget
✕3 blockers›
- Tissue heating caps implant power at a few hundred milliwatts, which bounds radio and compute
- Raw broadband neural data exceeds the link, forcing on-implant spike detection and compression
- Battery or wireless-power lifetime versus the decades a permanent interface implies
TRL 5- Implant power density sets what telemetry and on-board compute are affordable
✕2 blockers›
- Cycle life of lithium-metal anodes
- Thermal runaway safety
TRL 6
- Brain-wide coverage without surgery requires cell-scale devices that self-distributeplausibleTRL 3
- A lace grown in a child must function for centuries without scarringTRL 4
- A lace delivers experience and communication inward, not only data outward
✕4 blockers›
- Simultaneous stimulation and recording on the same tissue; stimulation artifact swamps spikes
- Coverage; immersive vision alone implies millions of controllable sites across V1
- Suppressing the real senses so the artificial stream is not in conflict with them
- Total implant power and heat once millions of channels are driven
plausibleTRL 3- Translating a synthetic scene into the activity patterns that evoke it
✕3 blockers›
- Models are subject-specific; decoders do not transfer across brains without recalibration
- Non-invasive signals are slow and spatially coarse; invasive coverage is a few square centimetres
- Encoding (write) models are far behind decoding; we cannot specify the activity for an arbitrary percept
TRL 3- Fast, fine-grained signals needed for anything beyond coarse category decodingTRL 6
- Deep generative and language models supply the latent spaces that brain activity is mapped onto
✕2 blockers›
- Reliability and calibration over long horizons
- Continual learning after deployment
TRL 7- Training and inference compute
✕2 blockers›
- Grid power and interconnection queues
- Advanced-node chip and HBM memory supply
TRL 8
- The write path for each sensory modality
✕4 blockers›
- Channel count and spatial resolution; phosphenes are coarse and do not tile a visual field
- Charge-density safety limits cap how often and how strongly tissue can be driven
- Stimulation artifacts blind the recording channels needed for closed-loop control
- No model specifies the pattern for an arbitrary complex percept
TRL 5- Stimulation needs the same dense chronic arrays as recordingTRL 6
- A full sensorium is a multi-gigabit bidirectional streamTRL 5
- Dense chronic coverage of multiple cortical areasTRL 6
- Direct network access to cortex requires authentication and bounded stimulation
✕3 blockers›
- Implant power and latency budgets limit cryptographic strength and attestation
- Decoders leak content the user did not intend to transmit; filtering requires classifying intent
- No verified safety kernel that bounds stimulation regardless of compromised higher software
TRL 4- Security must fit inside the implant's power and bandwidth budgetTRL 5
- Networked thought implies continuous high-rate wireless links through the skullTRL 5
Who could unlock it
- Across several requirements:
- Paradromics 4
- Neuralink 4
- Jacob Robinson 2
- Jia Liu 2
- Ken Shepard 2
In-vivo recording of a whole brain at single-neuron resolutionTRL 2bottleneck
- Alipasha VaziriResearcher, The Rockefeller UniversityLight beads microscopy recorded up to 1 million neurons across mouse dorsal cortex (Neuron 2024)
- Mikhail ShapiroResearcher, CaltechDevelops ultrasound and acoustic reporter genes for deep, noninvasive brain-activity readout
- Arbor Neuroscience (formerly Forest Neurotech)ProgramConvergent Research FRO founded 2023 by Caltech scientists to build whole-brain ultrasound sensing and modulation, backed by Eric and Wendy Schmidt
- Neuropixels consortium (HHMI Janelia, imec)ProgramDense silicon probes that record thousands of neurons per animal; the standard tool for large-scale electrophysiology
Injectable and self-implanting nanoscale neural interfacesTRL 3
- Deblina SarkarResearcher, MIT Media LabCirculatronics: immune-cell-electronics hybrids injected into the blood self-implanted in a target mouse brain region and were wirelessly powered (Nature Biotechnology 2025)
- Jacob RobinsonResearcher, Rice UniversityMagnetoelectric wireless power for distributed battery-free implant networks (Nature Biomedical Engineering 2025)
- Jia LiuResearcher, Harvard SEASCo-inventor of syringe-injectable mesh electronics; 2025 Nature Electronics paper on wireless ultrathin brain interfaces
- SynchronStartupEndovascular Stentrode in 10 patients by 2025; developing a transcatheter high-channel whole-brain interface
Full-sensorium bidirectional brain-computer interfaceTRL 3
- Robert GauntResearcher, University of Pittsburgh Rehab Neural Engineering LabsLeads the Pittsburgh ICMS program that showed biomimetic stimulation produces more natural touch in humans (J. Neural Eng. 2025)
- Eduardo FernándezResearcher, Miguel Hernández University of ElcheImplanted 96-channel arrays in visual cortex of blind volunteers who recognised letters and shapes (JCI 2021)
- NeuralinkStartupRaised $650M Series E in 2025; has human motor-BCI participants and FDA Breakthrough designations for vision and speech restoration
- ParadromicsStartupFirst long-term Connexus implant in June 2026; participant used it for real-time speech, with sensory feedback on the roadmap
Glial-scar-free chronic neural implant materialsTRL 4
- Jia LiuResearcher, Harvard SEASPioneer of tissue-like and syringe-injectable mesh electronics; co-founded Axoft
- AxoftStartupSoft Fleuron polymer probe completed a first-in-human safety study in 2025; raised over $18M
- ParadromicsStartupReported four years of stable preclinical recording in 2026 with platinum-iridium microwires and a titanium hermetic package
- NeuralinkStartupThin polymer thread electrodes implanted in multiple human participants since 2024
Trustworthy neural implant securityTRL 4
- Luciano FloridiResearcher, Yale Digital Ethics CenterCo-authored the 2025 Neuroethics analysis of BCI cyber risk recommending mandated non-surgical update paths, strong authentication and transit encryption
- Rafael YusteResearcher, Columbia UniversityFounder of the neurorights movement; drove the first hard-law neural-data protections, starting with Colorado HB 24-1058 in force August 2024
- Neurorights FoundationProgramCo-drafted the neural-data amendments enacted in Colorado, California, Montana and Connecticut (2024-2025) and briefed the FTC in April 2025
- MIND Act of 2025 (S.2925)ProgramCantwell/Schumer/Markey bill directing the FTC to assess neural-data security gaps and bar federal agencies from non-compliant neurotechnology
Gigabit wireless telemetry and power for implantsTRL 5
- Ken ShepardResearcher, Columbia UniversityBISC single-chip implant streams 1,024 channels wirelessly via UWB, at least 100x the throughput of competing wireless BCIs (Nature Electronics 2025)
- Kampto NeurotechStartupColumbia and Stanford spin-off founded in 2025 to commercialise the BISC wireless implant
- NeuralinkStartupN1 implant streams ~1,000 channels wirelessly with on-implant spike detection in human participants
- ParadromicsStartupConnexus pairs a cortical array with a chest-implanted transceiver; first long-term human implant in 2026
Beyond engineering
- Implanting infants before they can consent
- Dependence on a benevolent network operator for mood and memory